Water supply and sewerage
Categories: Services, Photo Keywords: Engineering, Installation, Sewer system, Water line, Water supply
USM Astana offers a wide range of services for design, installation, repair and maintenance of water supply and sewerage systems
Maintenance and routine repairs of hot and cold water supply systems, water treatment:
- Maintenance:
1) Checking water pumps (cleaning and lubrication of bearings, checking mechanical seals, checking bolts tightening);
2) Checking sodium cation filter; its tightness and operation;
3) Checking bactericidal apparatus, its tightness and operation;
4) Checking tanks, reservoirs, their tightness;
5) Checking water supply networks (detection of leakage);
6) Recording and documentation of water wastage;
7) Checking manholes and hatch covers;
8) Ensuring proper operation (or only in a workable) of equipment;
9) Ensuring there is no extraneous noise, vibration during equipment operation.
- Ongoing repairs:
1) Complete or partial modification of water points;
2) Changing input or output pipes;
3) Complete or partial re-laying of individual sections of pipelines due to outbreaks, corrosion or pipe subsidence;
4) Repair or replacement of valves;
5) Repair of pumps with opening, disassembly of mechanical seal, replacement of stuffing seals, checking condition of impeller and shaft and their replacement if necessary;
6) Pump centering;
7) Ramming stuffing boxes, replacement of individual parts of the valves;
8) Changing manholes and water wells covers;
9) Repair of shackles, stairs, and water supply pipe wells;
10) Elimination of leaks in water supply system;
11) System testing (pressure molding).
Maintenance and routine repair of sewerage systems:
- Maintenance:
1) Ensuring proper condition and cleanliness of manholes, proper covering with hatch;
2) Checking integrity of hatches;
3) Checking necks, shackles and stairs;
4) Checking degree of pipes filling; avoiding backwater (flooding), clogging and other defects visible from the ground surface;
5) Avoiding blockages on road near wells area and in trays for drainage of industrial waste, from the pumping room, and checking drainage pits and grids;
6) Checking internal sewage system (toilet facilities, bathrooms);
- Ongoing repairs:
1) Repair of parts with building defects or insufficient gradients;
2) Re-laying necks;
3) Complete redevelopment of wells.
Please contact us in any convenient way for you:
53 Kabanbay batyr avenue
Yessil district, Astana
Nazarbayev University campus
E-mail: usmcomments@nu.edu.kz
Tel.: +7 (7172) 70-61-29
+7 (702) 911 14 46